/usr/lib/osa/bin/lad # Lists all RAID devices connected to the system
c2t0d0 1T04359725 LUNS: 0 1
/usr/lib/osa/bin/healthck <c2t0d0> # General check of selected device
Health Check Summary Information
mya1000_001: Failed Battery # <– Failing battery
mya1000_001: Dead LUN at Drive [2,0] # <– Disk in bad state
healthck succeeded!
/usr/lib/osa/bin/raidutil -c <c2t0d0> # Generic information about the device
LUNs found on c2t0d0.
LUN 0 RAID 0 103407 MB
LUN 1 RAID 0 103407 MB
raidutil succeeded!
/usr/lib/osa/bin/raidutil -c <c2t0d0> -i # Detailed information
LUNs found on c2t0d0.
LUN 0 RAID 0 103407 MB
LUN 1 RAID 0 103407 MB
Vendor ID Symbios
ProductID StorEDGE A1000
Product Revision 0301
Boot Level 03.01.02.33
Boot Level Date 06/16/99
Firmware Level 03.01.02.35
Firmware Date 08/12/99
raidutil succeeded!
/usr/lib/osa/bin/raidutil -c <c2t0d0> -B # Information about battery life
LUNs found on c2t0d0.
LUN 0 RAID 0 103407 MB
LUN 1 RAID 0 103407 MB
Battery age is between 810 days and 900 days.
raidutil succeeded!
# Battery age:
# Between 630 and 720 days – near expiration
# More than 720 días – Expired
# In any of two previous cases battery should be replaced
/usr/lib/osa/bin/raidutil -c <c2t0d0> -R # Reset battery life counter
# RUN ONLY IF BATTERY HAS BEEN REPLACED!!!
/usr/lib/osa/bin/drivutil -I <c2t0d0> # Information about LUNs
Group Information for mya1000_001
Group No. of RAID No. of Total Remaining
LUNs Level Drives Space(MB) Space(MB)
1 1 0 6 103407 0
2 1 0 6 103407 0
drivutil succeeded!
/usr/lib/osa/bin/drivutil -i <c2t0d0> # Information about each of the drives
Drive Information for mya1000_001
Location Capacity Status Vendor Product Firmware Serial
(MB) ID Version Number
[1,0] 17274 Optimal SEAGATE ST318404LSUN18G 4207 3BT1BM1N00
[2,0] 17274 Optimal SEAGATE ST318404LSUN18G 4207 3BT0ZW4E00
[1,1] 17274 Optimal SEAGATE ST318305LSUN18G 0340 3JKP6AD900
[2,1] 17274 Optimal SEAGATE ST318404LSUN18G 4207 3BT19FG200
[1,2] 17274 Optimal SEAGATE ST318404LSUN18G 4207 3BT1BFZP00
[2,2] 17274 Optimal SEAGATE ST318404LSUN18G 4207 3BT1C09X00
[1,3] 17274 Optimal SEAGATE ST318404LSUN18G 4207 3BT1CC6T00
[2,3] 17274 Optimal SEAGATE ST318404LSUN18G 4207 3BT1BSBJ00
[1,4] 17274 Optimal SEAGATE ST318404LSUN18G 4207 3BT1BHY800
[2,4] 17274 Optimal SEAGATE ST318404LSUN18G 4207 3BT1CDN300
[1,5] 17274 Optimal IBM DDYST1835SUN18G S94N 00391G1084
[2,5] 17274 Optimal SEAGATE ST318404LSUN18G 4207 3BT1C5TT00
drivutil succeeded!
/usr/lib/osa/bin/rm6 # RAID MANAGER Graphic interface