Useful URL’s for management

Huawei OceanStor

Management – https://XXX.XXX.XXX.XXX:8088

Dell

HPE

IBM

VMWARE

Management Appliance – https://XXX.XXX.XXX.XXX:5480
Management – https://XXX.XXX.XXX.XXX:8088
Management – https://XXX.XXX.XXX.XXX:8088

Determine SSD Power on Hours

GUI
Smart Storage Administrator GUI allows to see the Power On Hours. In the SSA GUI, select the drive and review the Physical Drive details -> Power On Hours:Smart Storage Administrator (SSA) –Quick Guide to Determine SSD Power on Hours

ADUReport
Power On Hours can also be seen on the SSD Wear Gauge section for each drive in the ADU report:

https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00092478en_us

Bulletin: (Revision) HPE SAS Solid State Drives – Critical Firmware Upgrade Required for Certain HPE SAS Solid State Drive Models to Prevent Drive Failure at 40,000 Hours of Operation
https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00097382en_us


Default passwords

IBM

3576-L5B Operator Panel Username admin Password secure

DELL

MD3200i Username Administrator Password supportDell

Huawei

OceanStor Default username and password: admin / Admin@storage

hpssacli

Show configuration:
/opt/hp/hpssacli/bin/hpssacli ctrl all show config

Controller status
/opt/hp/hpssacli/bin/hpssacli ctrl all show status

Show detailed controller information for all controllers
/opt/hp/hpssacli/bin/hpssacli ctrl all show detail

Show detailed controller information for controller in slot 0
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 show detail

Rescan for New Devices
/opt/hp/hpssacli/bin/hpssacli rescan

Physical disk status
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show status

Show detailed physical disk information
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show detail

Logical disk status
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld all show status

View Detailed Logical Drive Status
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 show

Create New RAID 0 Logical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0

Create New RAID 1 Logical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1

Create New RAID 5 Logical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5

Delete Logical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 delete

Add New Physical Drive to Logical Volume
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7

Add Spare Disks
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7

Enable Drive Write Cache
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=enable

Disable Drive Write Cache
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=disable

Erase Physical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd 2I:1:6 modify erase

Turn on Blink Physical Disk LED
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=on

Turn off Blink Physical Disk LED
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=off

Modify smart array cache read and write ratio (cacheratio=readratio/writeratio)
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify cacheratio=100/0

Enable smart array write cache when no battery is present (No-Battery Write Cache option)
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify nbwc=enable

Disable smart array cache for certain Logical Volume
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable

Enable smart array cache for certain Logical Volume
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable

Enable SSD Smart Path
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=enable

Disable SSD Smart Path
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=disable

 

Running ADU report without hpacucli

cd /opt/hp/hpssaducli/bin
[test]:/opt/hp/hpssaducli/bin # ls
hpssaducli hpssaduesxi upgrade.txt
[test]:/opt/hp/hpssaducli/bin # ./hpssaducli -f /tmp/adu-report.zip
HP Smart Storage Diagnostics 1.60.17.0

Posted in HP

HPE Battery Matrix

Part number Controller Description Part number Battery Description