Huawei OceanStor
Management – https://XXX.XXX.XXX.XXX:8088
Dell
HPE
IBM
VMWARE
Management Appliance – https://XXX.XXX.XXX.XXX:5480
Management – https://XXX.XXX.XXX.XXX:8088
Management – https://XXX.XXX.XXX.XXX:8088
Huawei OceanStor
Management – https://XXX.XXX.XXX.XXX:8088
Dell
HPE
IBM
VMWARE
Management Appliance – https://XXX.XXX.XXX.XXX:5480
Management – https://XXX.XXX.XXX.XXX:8088
Management – https://XXX.XXX.XXX.XXX:8088
GUI
Smart Storage Administrator GUI allows to see the Power On Hours. In the SSA GUI, select the drive and review the Physical Drive details -> Power On Hours:Smart Storage Administrator (SSA) –Quick Guide to Determine SSD Power on Hours
ADUReport
Power On Hours can also be seen on the SSD Wear Gauge section for each drive in the ADU report:
https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00092478en_us
Bulletin: (Revision) HPE SAS Solid State Drives – Critical Firmware Upgrade Required for Certain HPE SAS Solid State Drive Models to Prevent Drive Failure at 40,000 Hours of Operation
https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00097382en_us
IBM
3576-L5B Operator Panel Username admin Password secure
DELL
MD3200i Username Administrator Password supportDell
Huawei
OceanStor Default username and password: admin / Admin@storage
Show configuration:
/opt/hp/hpssacli/bin/hpssacli ctrl all show config
Controller status
/opt/hp/hpssacli/bin/hpssacli ctrl all show status
Show detailed controller information for all controllers
/opt/hp/hpssacli/bin/hpssacli ctrl all show detail
Show detailed controller information for controller in slot 0
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 show detail
Rescan for New Devices
/opt/hp/hpssacli/bin/hpssacli rescan
Physical disk status
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show status
Show detailed physical disk information
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show detail
Logical disk status
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld all show status
View Detailed Logical Drive Status
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 show
Create New RAID 0 Logical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0
Create New RAID 1 Logical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1
Create New RAID 5 Logical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5
Delete Logical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 delete
Add New Physical Drive to Logical Volume
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7
Add Spare Disks
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7
Enable Drive Write Cache
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=enable
Disable Drive Write Cache
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=disable
Erase Physical Drive
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd 2I:1:6 modify erase
Turn on Blink Physical Disk LED
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=on
Turn off Blink Physical Disk LED
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=off
Modify smart array cache read and write ratio (cacheratio=readratio/writeratio)
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify cacheratio=100/0
Enable smart array write cache when no battery is present (No-Battery Write Cache option)
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify nbwc=enable
Disable smart array cache for certain Logical Volume
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable
Enable smart array cache for certain Logical Volume
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable
Enable SSD Smart Path
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=enable
Disable SSD Smart Path
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=disable
Running ADU report without hpacucli
cd /opt/hp/hpssaducli/bin
[test]:/opt/hp/hpssaducli/bin # ls
hpssaducli hpssaduesxi upgrade.txt
[test]:/opt/hp/hpssaducli/bin # ./hpssaducli -f /tmp/adu-report.zip
HP Smart Storage Diagnostics 1.60.17.0
Download https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX-b677f47e08794b8cba62d12c3f
run
hprsmcli.exe -s HOSTNAME -u root -p PASSWORD -o export.txt
Part number Controller | Description | Part number Battery | Description |
749800-001 | Smart Array P244BR 12G | 871265-001 (815984-001 is no longer supplied) | SPS-BATT PACK ENHANCED MegaCell 12W |