DISK BAD LABEL

Errors:
Mon Sep 7 21:54:19 CDT [aaaaaaaaaaa:raid.assim.disk.nolabe ls:error]: Disk 11c.28.9 Shelf 28 Bay 9 [NETAPP X422_SLTNG600A10 NA02] S/N [S0M1XFGM] has no valid labels. It will be taken out of service to prevent possible data loss.
Mon Sep 7 21:54:19 CDT [ aaaaaaaaaaa :raid.config.disk.bad.label:error]: Disk11c.28.9 Shelf 28 Bay 9 [NETAPP X422_SLTNG600A10 NA02] S/N [S0M1XFGM] has bad label.
Mon Sep 7 21:54:19 CDT [ aaaaaaaaaaa :callhome.dsk.label:CRITICAL]: Call home for DISK BAD LABEL
Mon Sep 7 21:55:00 CDT [ aaaaaaaaaaa :monitor.globalStatus.nonCritical:warning]: Disk on adapter 11c, shelf 28, bay 9, bad label.

Solution:

Use the following command:
priv set advanced
disk unfail -s <disk_name>

If above does not work the disk needs to be replaced!!

Determine SSD Power on Hours

GUI
Smart Storage Administrator GUI allows to see the Power On Hours. In the SSA GUI, select the drive and review the Physical Drive details -> Power On Hours:Smart Storage Administrator (SSA) –Quick Guide to Determine SSD Power on Hours

ADUReport
Power On Hours can also be seen on the SSD Wear Gauge section for each drive in the ADU report:

https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00092478en_us

Bulletin: (Revision) HPE SAS Solid State Drives – Critical Firmware Upgrade Required for Certain HPE SAS Solid State Drive Models to Prevent Drive Failure at 40,000 Hours of Operation
https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00097382en_us