showenvironment
consolehistory
consolehistory boot
consolehistory run
showsc
showfru
showfaults
showlogs
showhost
showenvironment
consolehistory
consolehistory boot
consolehistory run
showsc
showfru
showfaults
showlogs
showhost
sscli> show redundancy
sccli: selected se3000://10.7.1.1:58632 [SUN StorEdge 3310 SN#001234]
Primary controller serial number: 8012345
Redundancy mode: Active-Active
Redundancy status: Failed
Secondary controller serial number: 8004321
DUAL controller: Redundancy mode is Active-Active and the status is Enabled
SINGLE controller: Redundancy mode is Active-Active and the status is Scanning
format < /dev/null
prtdiag –v
iostat -En
metastat –t
metadb -i
zpool status -v
zpool history
zfs get all
prtconf -v
(for m-class systems)
To determine disk locations on XSCF run command showhardconf
bash]# sas2ircu 0 status
LSI Corporation SAS2 IR Configuration Utility.
Version 11.00.00.03 (2011.10.14)
Copyright (c) 2009-2011 LSI Corporation. All rights reserved.
[Wed May 23 14:39:45.546 2018] Background command progress status for controller 0…
[Wed May 23 14:39:45.551 2018] IR Volume 1
[Wed May 23 14:39:45.551 2018] Volume ID : 885
[Wed May 23 14:39:45.551 2018] Current operation : None
[Wed May 23 14:39:45.551 2018] Volume status : Enabled
[Wed May 23 14:39:45.551 2018] Volume state : Optimal
[Wed May 23 14:39:45.561 2018] Volume wwid : 0c21290b235ed52b
[Wed May 23 14:39:45.561 2018] Physical disk I/Os : Not quiesced
[Wed May 23 14:39:45.561 2018] IR Volume 2
[Wed May 23 14:39:45.561 2018] Volume ID : 886
[Wed May 23 14:39:45.561 2018] Current operation : None
[Wed May 23 14:39:45.561 2018] Volume status : Enabled
[Wed May 23 14:39:45.561 2018] Volume state : Optimal
[Wed May 23 14:39:45.561 2018] Volume wwid : 007128f03f8ed54c
[Wed May 23 14:39:45.561 2018] Physical disk I/Os : Not quiesced
[Wed May 23 14:39:45.561 2018] SAS2IRCU: Command STATUS Completed Successfully.
[Wed May 23 14:39:45.561 2018] SAS2IRCU: Utility Completed Successfully.
# sas2ircu 0 DISPLAY
LSI Corporation SAS2 IR Configuration Utility.
Version 11.00.00.03 (2011.10.14)
Copyright (c) 2009-2011 LSI Corporation. All rights reserved.
Read configuration has been initiated for controller 0
————————————————————————
Controller information
————————————————————————
Controller type : SAS2008
BIOS version : 7.21.04.00
Firmware version : 11.05.02.00
Channel description : 1 Serial Attached SCSI
Initiator ID : 0
Maximum physical devices : 831
Concurrent commands supported : 1024
Slot : Unknown
Segment : 0
Bus : 3
Device : 0
Function : 0
RAID Support : Yes
————————————————————————
IR Volume information
————————————————————————
IR volume 1
Volume ID : 885
Volume Name : vol1
Status of volume : Okay (OKY)
Volume wwid : 0c21290b235ed52b
RAID level : RAID1
Size (in MB) : 285148
Physical hard disks :
PHY[0] Enclosure#/Slot# : 1:3
PHY[1] Enclosure#/Slot# : 1:2
IR volume 2
Volume ID : 886
Volume Name : vol0
Status of volume : Okay (OKY)
Volume wwid : 007128f03f8ed54c
RAID level : RAID1
Size (in MB) : 285148
Physical hard disks :
PHY[0] Enclosure#/Slot# : 1:1
PHY[1] Enclosure#/Slot# : 1:0
————————————————————————
Physical device information
————————————————————————
Initiator at ID #0
Device is a Hard disk
Enclosure # : 1
Slot # : 0
SAS Address : 5000c50-0-3a02-de55
State : Optimal (OPT)
Size (in MB)/(in sectors) : 286102/585937499
Manufacturer : SEAGATE
Model Number : ST930003SSUN300G
Firmware Revision : 0B70
Serial No : 00111673M7YD
GUID : 5000c5003a02de57
Protocol : SAS
Drive Type : SAS_HDD
Device is a Hard disk
Enclosure # : 1
Slot # : 1
SAS Address : 5000cca-0-0a04-66cd
State : Optimal (OPT)
Size (in MB)/(in sectors) : 286102/585937499
Manufacturer : HITACHI
Model Number : H103030SCSUN300G
Firmware Revision : A2A8
Serial No : 000920G2E19E
GUID : 5000cca00a0466cc
Protocol : SAS
Drive Type : SAS_HDD
Device is a Hard disk
Enclosure # : 1
Slot # : 2
SAS Address : 5000cca-0-0a21-3f55
State : Optimal (OPT)
Size (in MB)/(in sectors) : 286102/585937499
Manufacturer : HITACHI
Model Number : H103030SCSUN300G
Firmware Revision : A2A8
Serial No : 000940GL8UTE
GUID : 5000cca00a213f54
Protocol : SAS
Drive Type : SAS_HDD
Device is a Hard disk
Enclosure # : 1
Slot # : 3
SAS Address : 5000c50-0-39fd-c489
State : Optimal (OPT)
Size (in MB)/(in sectors) : 286102/585937499
Manufacturer : SEAGATE
Model Number : ST930003SSUN300G
Firmware Revision : 0B70
Serial No : 00111673QE51
GUID : 5000c50039fdc48b
Protocol : SAS
Drive Type : SAS_HDD
Device is a Sequential access device
Enclosure # : 2
Slot # : 0
SAS Address : 5080020-0-00ea-75bd
State : Standby (SBY)
Manufacturer : SUN
Model Number : NEM Hydra II
Firmware Revision : 0308
Serial No : x365380
GUID : N/A
Protocol : SAS
Drive Type : SAS_HDD
Device is a Sequential access device
Enclosure # : 3
Slot # : 32
SAS Address : 5080020-0-0095-b5fd
State : Standby (SBY)
Manufacturer : SUN
Model Number : Blade Storage II
Firmware Revision : 0308
Serial No : x365380
GUID : N/A
Protocol : SAS
Drive Type : SAS_HDD
Device is a Hard disk
Enclosure # : 4
Slot # : 0
SAS Address : 5000cca-0-0a77-14d1
State : Ready (RDY)
Size (in MB)/(in sectors) : 286102/585937499
Manufacturer : HITACHI
Model Number : H103030SCSUN300G
Firmware Revision : A2A8
Serial No : 1013G3H6DE
GUID : 5000cca00a7714d0
Protocol : SAS
Drive Type : SAS_HDD
Device is a Hard disk
Enclosure # : 4
Slot # : 1
SAS Address : 5000c50-0-31b6-6541
State : Ready (RDY)
Size (in MB)/(in sectors) : 286102/585937499
Manufacturer : SEAGATE
Model Number : ST930003SSUN300G
Firmware Revision : 0B70
Serial No : 1049721A3L
GUID : 5000c50031b66543
Protocol : SAS
Drive Type : SAS_HDD
Device is a Hard disk
Enclosure # : 4
Slot # : 2
SAS Address : 5000cca-0-0ac7-e811
State : Ready (RDY)
Size (in MB)/(in sectors) : 286102/585937499
Manufacturer : HITACHI
Model Number : H103030SCSUN300G
Firmware Revision : A2A8
Serial No : 1035GJY5UE
GUID : 5000cca00ac7e810
Protocol : SAS
Drive Type : SAS_HDD
Device is a Hard disk
Enclosure # : 4
Slot # : 3
SAS Address : 5000c50-0-31bd-d229
State : Ready (RDY)
Size (in MB)/(in sectors) : 286102/585937499
Manufacturer : SEAGATE
Model Number : ST930003SSUN300G
Firmware Revision : 0B70
Serial No : 10497221X6
GUID : 5000c50031bdd22b
Protocol : SAS
Drive Type : SAS_HDD
Device is a Hard disk
Enclosure # : 4
Slot # : 4
SAS Address : 5000c50-0-31bb-9cf5
State : Ready (RDY)
Size (in MB)/(in sectors) : 286102/585937499
Manufacturer : SEAGATE
Model Number : ST930003SSUN300G
Firmware Revision : 0B70
Serial No : 104971ZJTE
GUID : 5000c50031bb9cf7
Protocol : SAS
Drive Type : SAS_HDD
Device is a Hard disk
Enclosure # : 4
Slot # : 5
SAS Address : 5000c50-0-31bd-d175
State : Ready (RDY)
Size (in MB)/(in sectors) : 286102/585937499
Manufacturer : SEAGATE
Model Number : ST930003SSUN300G
Firmware Revision : 0B70
Serial No : 10497221WM
GUID : 5000c50031bdd177
Protocol : SAS
Drive Type : SAS_HDD
Device is a Hard disk
Enclosure # : 4
Slot # : 6
SAS Address : 5000c50-0-31b6-6699
State : Ready (RDY)
Size (in MB)/(in sectors) : 286102/585937499
Manufacturer : SEAGATE
Model Number : ST930003SSUN300G
Firmware Revision : 0B70
Serial No : 1049720V47
GUID : 5000c50031b6669b
Protocol : SAS
Drive Type : SAS_HDD
Device is a Hard disk
Enclosure # : 4
Slot # : 7
SAS Address : 5000c50-0-31bd-faad
State : Ready (RDY)
Size (in MB)/(in sectors) : 286102/585937499
Manufacturer : SEAGATE
Model Number : ST930003SSUN300G
Firmware Revision : 0B70
Serial No : 104972227Q
GUID : 5000c50031bdfaaf
Protocol : SAS
Drive Type : SAS_HDD
Device is a Sequential access device
Enclosure # : 4
Slot # : 32
SAS Address : 5080020-0-009b-fdfd
State : Standby (SBY)
Manufacturer : SUN
Model Number : Blade Storage II
Firmware Revision : 0308
Serial No : x365380
GUID : N/A
Protocol : SAS
Drive Type : SAS_HDD
————————————————————————
Enclosure information
————————————————————————
Enclosure# : 1
Logical ID : 500605b0:06d56fc0
Numslots : 8
StartSlot : 0
Enclosure# : 2
Logical ID : 50800200:00ea7580
Numslots : 1
StartSlot : 0
Enclosure# : 3
Logical ID : 50800200:0095b580
Numslots : 33
StartSlot : 0
Enclosure# : 4
Logical ID : 50800200:009bfd80
Numslots : 33
StartSlot : 0
————————————————————————
SAS2IRCU: Command DISPLAY Completed Successfully.
SAS2IRCU: Utility Completed Successfully.
IPMI :
ipmitool -I lan -H <SP IP> -U root fru print
ipmitool -I lan -H <SP IP> -U root sensor list
ipmitool -I lan -H <SP IP> -U root sunoem led get
ipmitool -I lan -H <SP IP> -U root sunoem sbled get all
ipmitool -I lan -H <SP IP> -U root sdr list all info
ipmitool -I lan -H <SP IP> -U root chassis status
ipmitool -I lan -H <SP IP> -U root chassis restart_cause
M-Series
– showstatus
– showlogs error
– showlogs event
– showhardconf
– showhardconf -u
– fmdump
– fmdump –m
– showboards -a (or showdcl -a)
– version -c xscf -v
ILOM : |
show faulty |
fmadm faulty |
show -d properties -level all / |
show -o table -level all /SYS |
show /SP/logs/event/list |
show /SP/faultmgmt |
RSC> help |
RSC> showenvironment |
RSC> consolehistory |
RSC> consolehistory boot — most recent POST and boot messages |
RSC> consolehistory run —> most recent data received fro server OS |
RSC> loghistory |
RSC> show |
RSC> showsc |